CAT5e, CAT6 and CAT6A Explained

Selecting network cable should start with the required network performance, installation environment and future requirements.

CAT5e, CAT6 and CAT6A are different categories of twisted-pair Ethernet cabling. The correct choice depends on the intended network and installation.

Practical example: wiring a new office

New-office cabling example
New-office cabling examplePlan, label and test the complete channel rather than treating cable as an isolated product. SwitchActive networkPatch panelRack terminationHorizontal cablePermanent linkOutletWork area Plan, label and test the complete channel rather than treating cable as an isolated product.

Plan, label and test the complete channel rather than treating cable as an isolated product.

Scenario: A new office requires 48 desk outlets, wireless access points, VoIP phones and IP cameras.

The design works backwards from outlet locations to patch panels and switches. Permanent horizontal cabling is kept separate from replaceable patch leads. Cable category, shielding requirements, PoE use, pathways, labelling and rack termination are decided before installation.

Verification: Completed links are tested and documented. A simple continuity result should not be confused with certification against a cabling performance standard.

Common mistakes and selection checklist

Common mistakes

  • Treating patch leads, permanent horizontal cable and installation cable as interchangeable.
  • Ignoring cable length, termination quality, pathway separation and PoE heat considerations.
  • Calling a basic continuity test a certification test.

What happens if you get it wrong?

A link can pass simple pin-to-pin continuity yet still fail to deliver the expected Ethernet performance. Poor labelling and termination also make faults expensive to locate later.

Selection checklist

  • Choose the cable category and shielding approach for the required application.
  • Keep permanent links and patch leads within the intended structured-cabling design.
  • Use compatible jacks, patch panels and termination methods.
  • Label both ends and document outlet-to-panel mapping.
  • Test installed links to the level required by the project.
CategoryPractical consideration
CAT5eEstablished Ethernet cabling option for suitable installations.
CAT6Common business cabling choice with additional performance margin compared with CAT5e.
CAT6AHigher-performance copper infrastructure option where the installation and network requirements justify it.

Do not look at the cable alone

The complete channel includes connectors, patch panels, patch leads and the network equipment at each end. The components need to be compatible with the intended installation.

Plan for the environment

Indoor and outdoor installations can have different environmental requirements. Shielding, cable construction, routing and termination should be considered as part of the installation.

Plan for the future

Structured cabling can remain in place for years while network equipment changes. Where practical, future requirements should therefore be considered before installing the cable.

Return to Cabling & Connectivity

How to use this information

Confirm the exact product specification, supported configuration and compatibility before ordering. Platform generation, firmware, licences and optional components can change what a product supports.