ETHERNET TROUBLESHOOTING
Why a Gigabit Ethernet Link Runs at 100 Mbps
A practical installer workflow for a device that should negotiate at 1 Gbps but links at Fast Ethernet speed.
Why a pair fault is a strong suspect
Cisco's Catalyst 1000 data sheet identifies 100BASE-TX as a two-pair interface and 1000BASE-T as a four-pair interface. A cabling fault affecting the additional pairs can therefore leave a usable Fast Ethernet path while preventing Gigabit Ethernet operation.
But do not assume the cable is always the cause
Also verify both endpoints actually support 1000BASE-T, that speed/duplex settings allow correct autonegotiation, and that the switch port has not been manually forced to 100 Mbps.
Installer sequence
- Record the negotiated speed and duplex on both ends.
- Check switch configuration and endpoint capability.
- Replace the device patch lead with a known-good four-pair lead.
- Replace the rack patch lead if present.
- Run wiremap on the permanent link.
- If wiremap passes but the problem remains, certify the link or inspect performance results.
- Check interface errors after the link returns to 1 Gbps.