CERTIFICATION RESULTS

How to Read Ethernet Cable Certification Results

A field guide to wiremap, insertion loss, NEXT, PSNEXT, ACR-F, return loss, delay and skew.

Start with configuration before the numbers

Before interpreting any margin, confirm the cable ID, selected standard/category, permanent-link or channel configuration and tester adapters. A technically perfect-looking graph from the wrong test limit is not the evidence the project asked for.

Read failures in a useful order

  1. Wiremap.
  2. Length.
  3. Insertion loss.
  4. NEXT and power-sum crosstalk.
  5. Return loss.
  6. Far-end crosstalk metrics.
  7. Delay and skew.

NEXT

NEXT measures near-end crosstalk between pair combinations. Poor margin near one termination can point the installer toward pair dressing, untwist, connector termination or component issues. Use the tester's reported end and frequency information instead of reterminating both ends blindly.

Return loss

Return loss is associated with signal reflections caused by impedance discontinuities. Cable deformation, kinks, connector mismatch and termination geometry are examples of areas to investigate. A return-loss failure does not automatically identify one physical cause, so use location information and controlled substitution.

Insertion loss

Insertion loss is signal attenuation through the link. Length contributes directly, but connectors and cable construction also contribute. A link near the maximum allowed loss deserves inspection even when wiremap is perfect.

Keep the native data

Native certification records often contain graphs, frequencies, margins and diagnostic detail that a one-page PDF summary hides. Keep them with the cable schedule for later troubleshooting.

Back to Testing & Certification Centre

Technical references

These sources support the standards, test-method and manufacturer-specific statements on this page. Project specifications and current manufacturer documentation take precedence for a real installation.